The RFID reader is TYPE and is plugged directly into the control board. | The RFID reader is TYPE and is plugged directly into the control board. | ||
This is the wiring scheme that comes directly out of the reader. The wires that come out of the wall are listed below. | |||
*Red - +12v DC | *Red - +12v DC | ||
*Black - GND | *Black - GND | ||
| Line 41: | Line 42: | ||
*Orange - Doorbell switch | *Orange - Doorbell switch | ||
*Brown - Doorbell switch | *Brown - Doorbell switch | ||
=Wiring= | |||
There are 2 wiring buses in parallel to make the doorbell/doorstrike/data transfer work. They connect to 2 terminal blocks at each doorway. Everything currently runs on 12v. | |||
===Brown 8 conductor wire=== | |||
This wire supports the doorbell button, strike actuation, and ring. | |||
*Red - +12v DC | |||
*Black - GND | |||
*White - | |||
*Green - | |||
*Blue - | |||
*Yellow - | |||
*Orange - Back door strike | |||
*Brown - Front door strike | |||
===Grey CAT3 6-pair wire=== | |||
This wire supports the RFID reader wires directly. Note that the twisted pairs are different than normal. | |||
The Cat 3 was used to extend the short RFID wire and below is how the wires map. Note: the Grey and Yellow wires from the RFID reader are not connected to the Cat 3 and terminate in the tube that passes the cable through the wall. | |||
*Red and Blue striped pair - Red - +12v DC | |||
*White/Grey and Grey pair - Black - GND | |||
*White/Green and White/Blue pair - White - D1 / TX | |||
*Green - Green - D0 / RX | |||
*Blue - Blue - LED | |||
*White/Orange and Orange pair - Doorbell switch | |||
*White/Brown and Brown pair - Doorbell switch | |||