RFIDv2: Difference between revisions

From Pumping Station One
Line 31: Line 31:
The RFID reader is TYPE and is plugged directly into the control board.
The RFID reader is TYPE and is plugged directly into the control board.


Wiring colors
This is the wiring scheme that comes directly out of the reader. The wires that come out of the wall are listed below.
 
*Red - +12v DC
*Red - +12v DC
*Black - GND
*Black - GND
Line 41: Line 42:
*Orange - Doorbell switch
*Orange - Doorbell switch
*Brown - Doorbell switch
*Brown - Doorbell switch
=Wiring=
There are 2 wiring buses in parallel to make the doorbell/doorstrike/data transfer work. They connect to 2 terminal blocks at each doorway.  Everything currently runs on 12v.
===Brown 8 conductor wire===
This wire supports the doorbell button, strike actuation, and ring.
*Red - +12v DC
*Black - GND
*White -
*Green -
*Blue -
*Yellow -
*Orange - Back door strike
*Brown - Front door strike
===Grey CAT3 6-pair wire===
This wire supports the RFID reader wires directly. Note that the twisted pairs are different than normal.
The Cat 3 was used to extend the short RFID wire and below is how the wires map. Note: the Grey and Yellow wires from the RFID reader are not connected to the Cat 3 and terminate in the tube that passes the cable through the wall.
*Red and Blue striped pair - Red - +12v DC
*White/Grey and Grey pair - Black - GND
*White/Green and White/Blue pair - White - D1 / TX
*Green - Green - D0 / RX
*Blue - Blue - LED
*White/Orange and Orange pair - Doorbell switch
*White/Brown and Brown pair - Doorbell switch