Electrical: Difference between revisions

From Pumping Station One
Wessing (talk | contribs)
Wessing (talk | contribs)
Line 178: Line 178:
! Breaker # !! Used !! Amperage !! What Is It
! Breaker # !! Used !! Amperage !! What Is It
|-  
|-  
| 1 || in use || 100 || Main breaker for box - Tandem with 3
| 1 || in use || 100 || Main breaker for box - Tandem with #3
|-
|-
| 3 || in use || 100 || Main Breaker for box - Tandem with 1
| 3 || in use || 100 || Main Breaker for box - Tandem with #1
|-  
|-  
| 5 || || 20 || Tandem with 7
| 5 || || 20 || Tandem with #7
|-
|-
| 6 || || 20 ||
| 6 || || 20 ||
|-
|-
| 7 || || 20 || Tandem with 5
| 7 || || 20 || Tandem with #5
|-
|-
| 8 || in use || 20 || Back stairwell lights, catwalk lights, night light in the shop..
| 8 || in use || 20 || Back stairwell lights, catwalk lights, night light in the shop..
Line 214: Line 214:
| 20 || in use || 15 || Outlet in closet
| 20 || in use || 15 || Outlet in closet
|-
|-
| 21 || || 30 || Tandem with 23
| 21 || || 30 || Tandem with #23
|-
|-
| 22 || unused || none ||
| 22 || unused || none ||
|-
|-
| 23 || || 30 || Tandem with 21
| 23 || || 30 || Tandem with #21
|-
|-
| 24 || unused || none ||
| 24 || unused || none ||
Line 238: Line 238:
| 2 || in use || 20 || 2 lower outlets, in kitchen either side of door. Outlet at SEM location
| 2 || in use || 20 || 2 lower outlets, in kitchen either side of door. Outlet at SEM location
|-
|-
| 3 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 3 || Not used || none || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 4 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 4 || Not used || none || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 5 || in use || split 20 || 2 circuits a&b, Beer church.
| 5 || in use || split 20 || 2 circuits a&b, Beer church.
Line 246: Line 246:
| 6 || in use || 20 || Tandem with #8 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
| 6 || in use || 20 || Tandem with #8 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
|-
|-
| 7 || in use || || ?
| 7 || in use || 20 ||  
|-
|-
| 8 || in use || 20 || Tandem with #6 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
| 8 || in use || 20 || Tandem with #6 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
|-
|-
| 9 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 9 || Not used || none || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 10 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 10 || Not used || none || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 11 ||  in use || 20 || Laser
| 11 ||  in use || 20 || Laser
|-
|-
| 12 || in use || 20 || Tandem with #14 - 240v, kitchen,above counter. For induction cook top
| 12 || in use || 20 || Tandem with #14 - 240v, kitchen, above counter. For induction cook top
|-
|-
| 13 || || ||
| 13 || in use || 30 || Tandem with #15 & #17 - Bridgeport
|-
|-
| 14 || in use  || 20 ||Tandem with #12 - 240v, kitchen,above counter. For induction cook top
| 14 || in use  || 20 ||Tandem with #12 - 240v, kitchen, above counter. For induction cook top
|-
|-
| 15 || || ||
| 15 || in use || 30 || Tandem with #13 & #17 - Bridgeport
|-
|-
| 16 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 16 || Not used || none || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 17 || || ||
| 17 || in use || 30 || Tandem with #13 & #15 - Bridgeport
|-
|-
| 18 || in use || 20 || Outlet at SEM location
| 18 || in use || 20 || Outlet at SEM location