Electrical: Difference between revisions
From Pumping Station One
| Line 232: | Line 232: | ||
{|Class="wikitable sortable" border="1" style="td { border: 1px solid #000000}" | {|Class="wikitable sortable" border="1" style="td { border: 1px solid #000000}" | ||
|- | |- | ||
! Breaker # !! Used !! What Is It | ! Breaker # !! Used !! Amperage !! What Is It | ||
|- | |- | ||
| 1 || in use || 20 | | 1 || in use || 20 || above kitchen ceiling, servers on catwalk | ||
|- | |- | ||
|2|| in use || 20 | | 2 || in use || 20 || 2 lower outlets, in kitchen either side of door. Outlet at SEM location | ||
|- | |- | ||
| 3 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit. | | 3 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit. | ||
|- | |- | ||
| 4 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit. | | 4 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit. | ||
|- | |- | ||
| 5 || in use || split 20 | | 5 || in use || split 20 || 2 circuits a&b, Beer church. | ||
|- | |- | ||
| 6 || in use || | | 6 || in use || 20 || Tandem with #8 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps | ||
|- | |- | ||
| 7 || in use || ? | | 7 || in use || || ? | ||
|- | |- | ||
| 8 || in use || | | 8 || in use || 20 || Tandem with #6 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps | ||
|- | |- | ||
| 9 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit. | | 9 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit. | ||
|- | |- | ||
| 10 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit. | | 10 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit. | ||
|- | |- | ||
| 11 || in use || 20 | | 11 || in use || 20 || Laser | ||
|- | |- | ||
|12 || in use || | | 12 || in use || 20 || Tandem with #14 - 240v, kitchen,above counter. For induction cook top | ||
|- | |- | ||
|13 || || | | 13 || || || | ||
|- | |- | ||
| 14 || in use || | | 14 || in use || 20 ||Tandem with #12 - 240v, kitchen,above counter. For induction cook top | ||
|- | |- | ||
| 15 || | | 15 || || || | ||
|- | |- | ||
| 16 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit. | | 16 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit. | ||
|- | |- | ||
| 17 || || | | 17 || || || | ||
|- | |- | ||
|18 || in use || 20 | | 18 || in use || 20 || Outlet at SEM location | ||
|} | |} | ||