Machine Repaired - Left extruder fan wiring shorted in wire loom causing power cycle when the left thermocouple read 50C+
Thermocouples were retaped to ensure electrical isolation from heater block - heater wire can fray and short out on the heater block.
5V pin was removed from the end stop cables.  This is reversible and protects against internal shorts in the endstop cables.  A short could permanently damage the Mightyboard.  End stop leds will not work but they still mechanically    function as intended.
A plastic cover was added to the back of the lcd to prevent accidental damage from grabbing bare conductors. --[[User:Junes|Junes]] ([[User talk:Junes|talk]]) 15:59, 28 October 2014 (CDT)
September 22, 2014: Machine reboots when it heats up.  
September 22, 2014: Machine reboots when it heats up.