Wood Shop Dust Collection: Difference between revisions
From Pumping Station One
m Robot: Cosmetic changes |
|||
| Line 1: | Line 1: | ||
Our shop needs *real* dust collection. | Our shop needs *real* dust collection. Here lies the start of plans to rectify that. | ||
==Dust Collector== | == Dust Collector == | ||
http://www.clearvuecyclones.com/cv-max/13-cv-max-three-phase-with-filters.html | http://www.clearvuecyclones.com/cv-max/13-cv-max-three-phase-with-filters.html | ||
| Line 7: | Line 7: | ||
5 HP motor (Leeson 132242.00 frame 184TC, 86.5% efficiency) | 5 HP motor (Leeson 132242.00 frame 184TC, 86.5% efficiency) | ||
This dust collector will have sufficient flow with two open gates. | This dust collector will have sufficient flow with two open gates. Occasional use with three gates open is acceptable. The 'nano' filter option ($100) is recommended. | ||
Collector cost with nano filter is $2070. | Collector cost with nano filter is $2070. | ||
| Line 14: | Line 14: | ||
Clearvue technical support does not recommend mixing wood and metal dust in the same collection system. | Clearvue technical support does not recommend mixing wood and metal dust in the same collection system. | ||
==Ducting== | == Ducting == | ||
6" sewer & drain pipe for drops | 6" sewer & drain pipe for drops | ||
| Line 21: | Line 21: | ||
8" sewer & drain pipe for main lines | 8" sewer & drain pipe for main lines | ||
==Automating this stuff== | == Automating this stuff == | ||
No one will use it if it doesn't turn on automatically. It *must* be automatic. I've read that using less than 3" ducts with a large 15-16" blower is a problem. | No one will use it if it doesn't turn on automatically. It *must* be automatic. I've read that using less than 3" ducts with a large 15-16" blower is a problem. | ||
| Line 28: | Line 28: | ||
* [[File:Blast gate.doc]] | * [[File:Blast gate.doc]] | ||
This is a 2.5" duct, 'cause I originally planned to use the shop vac. | This is a 2.5" duct, 'cause I originally planned to use the shop vac. The hole can just be enlarged to 3" w/o other changes. For 4" or 6" gates, the plates should be enlarged, and linkages will probably need lengthening. I made a lot of paper models to get the geometry right. Someone with experience modelling moving parts with CAD could probably do the scaling more quickly. | ||
[[File:blast_gate_front.svg]] | [[File:blast_gate_front.svg]] | ||
==Machines that need collection== | == Machines that need collection == | ||
* Table saw (needs retrofit 6" pipe inside and out, maybe 5" and an overhead 3" collector) | * Table saw (needs retrofit 6" pipe inside and out, maybe 5" and an overhead 3" collector) | ||
* Jointer | * Jointer | ||
| Line 44: | Line 44: | ||
* Drill presses | * Drill presses | ||
While all of these machines need dust/debris collection of some sort. | While all of these machines need dust/debris collection of some sort. Some of them may be better served by water buckets instead of a central dust vacuum. For instance grinders should have their exhausts feed into a bucket with water in it. | ||
==Electrical Needs== | == Electrical Needs == | ||
The dust collector should be on it's own circuit, switched on by a relay. | The dust collector should be on it's own circuit, switched on by a relay. Switches should be conveniently located near machines, or interlocked to certain machines. | ||
==Costs== | == Costs == | ||
Clearvue CVMAX 3 phase with nano filters $2070 | Clearvue CVMAX 3 phase with nano filters $2070 | ||
| Line 64: | Line 64: | ||
y pieces of 8"x10' pvc pipe | y pieces of 8"x10' pvc pipe | ||
n 8x8x6 PVC wye | n 8x8x6 PVC wye $83 each | ||
mounting hardware $200 | mounting hardware $200 | ||