== Cooling ==
=== Lounge ====
There is a wall mount A/C unit that is sort of old and may contain mold in the lounge.
=== Shop ===
There is a heat pump / air handler cooling system mounted on the ceiling and roof.
These are some very vague and poorly collated notes about that:
    heat pump stat - but we aren't using the heat pump for heating, so we
    don't even need the fancy board since it's for defrost. we use it when
    we're cooling only. Right now, the wire from the roof is wired to make
    it so when power is on (7,9,11) PP1-1 - it runs all the time. There is
    no relay control of it that's active. the red wire in the control wire
    will throw a relay on and off to control the heat pump.
    but, we don't need to use the heat mode of the unit and it's not wired
    upstairs for it at the moment, so we should set up the filtrete like so -
      take off silver jumper
      use RC and Y. (normal cooling, not heat pump cooling - the transformer
    is ganged right to the relay up top).
      thin red wire on the transformer goes to RC
      thick red wire from the roof goes to Y
      blue and white should be stuck together like they are.
    we also need to put the air handler/fan unit on the coil that hangs down
    (big tan thing) run always if the heat pump is on, since it will ice up
    otherwise.  However, it's also useful when things aren't in cooling mode
    for running some air from outside to the shop, so we want a switch that
    can manually trigger the relay that will be controlling the air handler.
=== Upstairs ===
There is an AC unit in the comms/hvac closet upstairs near the side stairs. TBD documenting that.
== Heating Zones ==
== Heating Zones ==
The upstairs and the downstairs are the 2 separate heating zones.
The upstairs and the downstairs are the 2 separate heating zones.