Biosensor Array Body Temperature: Difference between revisions

From Pumping Station One
Ehanley (talk | contribs)
This page is part of the Biosensor Array Project
 
No edit summary
Line 1: Line 1:
The goal of this sensor is to provide regular measurement of the user's core body temperature. 
===Version 1.0===
==Sensor Specifications==
* It has been decided to locate the sensor in the armpit of the user as placing it in the mouth presents a choking hazard during physical activities. 
* The sensor chosen is the TMP102 breakout board available from Sparkfun Electronics: [[http://www.sparkfun.com/products/9418]]
**'''Advantages'''
***Digital I/O means we can use flexible wires as opposed to more brittle thermocouple wire that can break if kinked.
***Sparkfun provides a link to pre-existing Arduino code for this sensor hosted on the Wiring website: http://wiring.org.co/learning/libraries/tmp102sparkfun.html
***Small enough to fit under a person's armpit
***Reasonably fast response rate.
**'''Disadvantages'''
***Bare PCB requires some kind of enclosure or other potection from sweat and other moisture.
==Status==
* Communications testing complete - 4/10/2011
==To Be Completed==
* Selection of rugged multi-conductor data/power cable.
** Four conductors needed
* Selection of strain relief
* Selection of plug type for connecting to the on-body base unit
** BNC?
* Design and fabrication of sensor enclosure.
** 3/4" NPT Aluminum pipe fitting cap and 3/4" NPT Aluminum pipe fitting plug
====== This page is part of the [[Biosensor Array]] Project ======