'''Your work piece is not trash yet, but might be if you don't follow these steps''' | '''Your work piece is not trash yet, but might be if you don't follow these steps''' | ||
One of the following: | One of the following happened: | ||
* Touch off get stuck with torch touching the plate | * Touch off get stuck with torch touching the plate | ||
| Line 82: | Line 82: | ||
* Error probe ignored in status bar - If this is the case clean the shield nozzle, dross has gotten inside, do not move work piece | * Error probe ignored in status bar - If this is the case clean the shield nozzle, dross has gotten inside, do not move work piece | ||
Do This: | |||
# Hit escape '''ONCE''', not e-stop, not reset, escape | # Hit escape '''ONCE''', not e-stop, not reset, escape | ||
| Line 99: | Line 100: | ||
* Dross/corrosion on the plate cause a none conductive area where the torch touched off | * Dross/corrosion on the plate cause a none conductive area where the torch touched off | ||
* Torch cable has become too taught and caused the probe connection to come loose or the probe ring not to touch the torch shield | * Torch cable has become too taught and caused the probe connection to come loose or the probe ring not to touch the torch shield | ||
==== Torch fails to ignite ==== | ==== Torch fails to ignite ==== | ||