Mitsui Surface Grinder: Difference between revisions
From Pumping Station One
No edit summary |
Update repair and setup |
||
| Line 11: | Line 11: | ||
|value=~$3000}} | |value=~$3000}} | ||
== Repair == | == Repair and Setup== | ||
All repair needs to be coordinated with the area host. | All repair needs to be coordinated with the area host. | ||
Motor bearings were replaced, to great success. | Motor bearings were replaced, to great success. | ||
Ball ways and table are installed. | Ball ways and table are installed. Test grinds are showing good repeatability. A grit and light parts catcher is installed on the left hand side. | ||
# Remove saddle, clean ways and check turcite for damage. | # Remove saddle, clean ways and check turcite for damage. | ||
| Line 21: | Line 21: | ||
# Replace Z way pleated covers. | # Replace Z way pleated covers. | ||
# Fill lubrication tank with correct oil. Check that all oil lines are working. | # Fill lubrication tank with correct oil. Check that all oil lines are working. | ||
# Remove the grinder from the pallet and align parallel to the long wall. Set up the materials storage and maybe plywood on the right side. | |||
# Install a full wheel guard. | |||
# Develop an authorization plan. | |||
== Diagnosis == | == Diagnosis == | ||
After initial repair, diagnosis of further issues will come via a test grind. | After initial repair, diagnosis of further issues will come via a test grind. | ||
# The table | # The table may need to be ground in. | ||
# A mag chuck will need to be ground in. | # A mag chuck will need to be ground in and swept with an indicator. | ||
# Five block test can be used as a | # Five block test can be used as a rough diagnosis. | ||
== Table Removal == | == Table Removal == | ||