Talk:Gingery Plastic Injection Machine/doc: Difference between revisions
From Pumping Station One
Created page with "== Use == Obviously the heating unit and everything that is attached to '''the heating unit can get quite hot be careful'''. You may want to use a leather glove and pliers wh..." |
No edit summary |
||
| Line 4: | Line 4: | ||
You may want to use a leather glove and pliers while working near the heating unit. | You may want to use a leather glove and pliers while working near the heating unit. | ||
The control unit has a Mypin controller two | The control unit has a Mypin controller with two switches and a light. The left switch powers the controller. The controller must be on to enable the heating unit. The right switch and the controller power the heating unit. The right switch must be on (up) and the controller will turn on the heating unit until the SV temp is reached. | ||
| Line 22: | Line 22: | ||
== Mypin Temp Controller == | == Mypin Temp Controller == | ||
The temperature controller displays the current temperature of the heating element (PV) and the set value (SV). Both values are displayed in F. OUT1 = heating control, if | The temperature controller displays the current temperature of the heating element (PV) and the set value (SV). Both values are displayed in F. OUT1 = heating control, if lit the heating element is on. AL = alarm1, currently set to 400 degrees F. | ||
To change the | To change the SV, Press the </AT key to select the digit you want to modify. Press ^ or v to modify digit. Press SET to confirm. | ||