Electrical: Difference between revisions

From Pumping Station One
Wessing (talk | contribs)
Wessing (talk | contribs)
Line 232: Line 232:
{|Class="wikitable sortable" border="1" style="td { border: 1px solid #000000}"
{|Class="wikitable sortable" border="1" style="td { border: 1px solid #000000}"
|-
|-
! Breaker # !! Used !! What Is It
! Breaker # !! Used !! Amperage !! What Is It
|-
|-
| 1 || in use || 20 amp,above kitchen ceiling, servers on catwalk
| 1 || in use || 20 || above kitchen ceiling, servers on catwalk
|-
|-
|2|| in use || 20 amp, 2 lower outlets, in kitchen either side of door. Outlet at SEM location
| 2 || in use || 20 || 2 lower outlets, in kitchen either side of door. Outlet at SEM location
|-
|-
| 3 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 3 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 4 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 4 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 5 || in use || split 20 amp breaker, 2 circuits a&b, Beer church.
| 5 || in use || split 20 || 2 circuits a&b, Beer church.
|-
|-
| 6 || in use || paired with #8, 20 amp 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
| 6 || in use || 20 || Tandem with #8 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
|-
|-
| 7 || in use || ?
| 7 || in use || || ?
|-
|-
| 8 || in use || paired with #6, 20 amp 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
| 8 || in use || 20 || Tandem with #6 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
|-
|-
| 9 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 9 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 10 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 10 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 11 ||  in use || 20 amp, Laser
| 11 ||  in use || 20 || Laser
|-
|-
|12 || in use || paired with # 14, 20 amp 240v, kitchen,above counter. For induction cook top
| 12 || in use || 20 || Tandem with #14 - 240v, kitchen,above counter. For induction cook top
|-
|-
|13 || ||  
| 13 || || ||
|-
|-
| 14 || in use  || paired with # 12, 20 amp 240v, kitchen,above counter. For induction cook top
| 14 || in use  || 20 ||Tandem with #12 - 240v, kitchen,above counter. For induction cook top
|-
|-
| 15 || ||
| 15 || || ||
|-
|-
| 16 || Not used || 208 volts to neutral, not recommended for use except in 3 phase circuit.
| 16 || Not used || || 208 volts to neutral, not recommended for use except in 3 phase circuit.
|-
|-
| 17 || ||  
| 17 || || ||
|-
|-
|18 || in use || 20 amp, Outlet at SEM location
| 18 || in use || 20 || Outlet at SEM location
|}
|}