Retired clearvue Dust Collector: Difference between revisions

From Pumping Station One
Daddybird (talk | contribs)
Daddybird (talk | contribs)
Line 33: Line 33:
The clear plastic tube mounted near the filter stack is a manometer.  When the collector is running, the distance between the left and right columns of the manometer should be two inches or less.  If it exceeds this, flow through the filter will be reduced and it must be cleaned.  When the filter is clean, the back pressure will be less than 1.25".
The clear plastic tube mounted near the filter stack is a manometer.  When the collector is running, the distance between the left and right columns of the manometer should be two inches or less.  If it exceeds this, flow through the filter will be reduced and it must be cleaned.  When the filter is clean, the back pressure will be less than 1.25".


[[File:Manometer.jpg|thumb|left]]
[[File:Manometer.jpg|200px|left]]<br clear=all>
Manometer when the dust collector needs emptying. This is way more than the 1.25" backpressure that's acceptable.


=== Clean the filter ===
=== Clean the filter ===