Tormach 1300PL CNC Plasma Cutter: Difference between revisions
From Pumping Station One
Adding step by step instructions |
→Tool Chains: add cnc plasma file location |
||
| (6 intermediate revisions by 3 users not shown) | |||
| Line 20: | Line 20: | ||
==Consumables== | ==Consumables== | ||
[[File:Consumables.png|300px|thumb|center|]] | |||
== Tool Chains == | == Tool Chains == | ||
work in progress<br/> | work in progress<br/> | ||
Remote/cloud access. Pathpilot hub https://hub.pathpilot.com/about | Remote/cloud access. Pathpilot hub https://hub.pathpilot.com/about | ||
In order to post your job from the sheetcam pc attached to wall, navigate to: \\cncplasma\gcode in file explorer | |||
[[File:Image.png|thumb]] | |||
== Use == | == Use == | ||
[[Tormach CNC Plasma Cutter Debugging]] | [[Tormach CNC Plasma Cutter Debugging]] | ||
[[Tormach Plasma CNC Settings and Capabilities]] | |||
=== Step by Step === | === Step by Step === | ||
A work in progress, edit as needed <br/> | A work in progress, edit as needed <br/> | ||
| Line 43: | Line 47: | ||
Click the X,Y & Z Zero buttons.<br/> | Click the X,Y & Z Zero buttons.<br/> | ||
Select your material using the auto F&S selector drop downs. Note the amps required setting in the pop up window.<br/> | Select your material using the auto F&S selector drop downs. Note the amps required setting in the pop up window.<br/> | ||
==== Hypertherm Plasma setup ==== | ==== Hypertherm Plasma setup ==== | ||
Turn on Hypertherm machine at the back of the Tormach, you should see three green lights.<br/> | Turn on Hypertherm machine at the back of the Tormach, you should see three green lights.<br/> | ||
Check that Hypertherm Amps setting matches the amps required setting in the Pathpilot pop up window, adjust as necessary.<br/> | Check that Hypertherm Amps setting matches the amps required setting in the Pathpilot pop up window, adjust as necessary.<br/> | ||
==== Run your job ==== | ==== Run your job ==== | ||
If you haven’t already, load your Gcode, click the reset button if flashing.<br/> | If you haven’t already, load your Gcode, click the reset button if flashing.<br/> | ||
| Line 55: | Line 59: | ||
Run Job. Click cycle start.<br/> | Run Job. Click cycle start.<br/> | ||
*Be prepared to click stop or hit Estop if something seems wrong*<br/> | *Be prepared to click stop or hit Estop if something seems wrong*<br/> | ||
==== Shut Down ==== | ==== Shut Down ==== | ||
Set the Hypertherm plasma to 45 amps if needed and turn off the machine.<br/> | Set the Hypertherm plasma to 45 amps if needed and turn off the machine.<br/> | ||
| Line 61: | Line 65: | ||
Turn off the main switch on the control box.<br/> | Turn off the main switch on the control box.<br/> | ||
Clean up around the area and put any scrap metal in the garbage can that is marked for metal scrap only.<br/> | Clean up around the area and put any scrap metal in the garbage can that is marked for metal scrap only.<br/> | ||
== Maintenance == | == Maintenance == | ||