Schultz air compressor: Difference between revisions
From Pumping Station One
Garynhouse (talk | contribs) |
Garynhouse (talk | contribs) |
||
| (6 intermediate revisions by the same user not shown) | |||
| Line 8: | Line 8: | ||
|serial = 0003929870 | |serial = 0003929870 | ||
|arrived = Oct. 16, 2021 | |arrived = Oct. 16, 2021 | ||
|manual = https://wiki.pumpingstationone.org/images/SchultzMsw_60_max.pdf | |||
|where = Boiler Room | |where = Boiler Room | ||
|doesitwork = yes | |doesitwork = yes | ||
| Line 16: | Line 17: | ||
The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine. | The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine. | ||
| Line 38: | Line 37: | ||
== Maintenance == | == Maintenance == | ||
Manual is here in [https://wiki.pumpingstationone.org/images/SchultzMsw_60_max.pdf manual. ]pdf. Check oil frequently belts monthly and change oil every 200 hours. | |||
Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams. | Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams. | ||
| Line 60: | Line 59: | ||
-Check the pressure switch operation. | -Check the pressure switch operation. | ||
-Check for oil contamination and change it if necessary. | -Check for oil contamination and change it if necessary. | ||
-check and clean filters | |||
=== Bimonthly === | |||
- change oil every 200 working hours or every other month.(Whichever occurs first). | |||
- | |||
-Fasten bolts and nuts as required. | -Fasten bolts and nuts as required. | ||
-Change oil more frequently if compressor is located in a very dirty environment. | -Change oil more frequently if compressor is located in a very dirty environment. | ||