Acetylene Air Torch Jewelry: Difference between revisions

From Pumping Station One
Aushra (talk | contribs)
No edit summary
Api (talk | contribs)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Template:EquipmentPage
{{Template:EquipmentPage
|owner = PS:One (torch heads, regulator), Dean Anderson (tank)
|owner = PS:One
|hostarea = Small Metals
|hostarea = Small Metals
|certification = yes
|certification = yes
Line 43: Line 43:
# Close the torch handle valve (clockwise) to extinguish the flame.  Stop here if you'll be using it again soon.
# Close the torch handle valve (clockwise) to extinguish the flame.  Stop here if you'll be using it again soon.
# Shut the cylinder valve by turning the handle clockwise.
# Shut the cylinder valve by turning the handle clockwise.
# Open the torch handle valve to purge the hose of acetylene. Both pressure gauges should drop to 0.
# Open the torch handle valve to purge the hose of acetylene. '''Both''' pressure gauges should drop to 0.
# Close the torch handle valve.
# Close the torch handle valve.
# Turn the regulator T-handle counterclockwise until it is loose.
# Turn the regulator T-handle counterclockwise until it is loose.


== DO NOT USE AN EMPTY TANK ==
== DO NOT USE AN EMPTY TANK - 50 PSI is Empty ==
# If the right gauge is near 50-60 PSI (red numbers), send a message to smallmetals@pumpingstationone.org and the #small-metals Slack channel that the tank needs to be replaced.
# If the right gauge is near 50-60 PSI (red numbers), send a message to smallmetals@pumpingstationone.org and the #small-metals Slack channel that the tank needs to be replaced.
# If the right gauge is at or below 50 PSI: DO NOT USE the acetylene. Immediately shut down the tank and notify smallmetals@pumpingstationone.org and the #small-metals Slack channel that the tank needs to be replaced.
# If the right gauge is at or below 50 PSI: DO NOT USE the acetylene. Immediately shut down the tank and notify smallmetals@pumpingstationone.org and the #small-metals Slack channel that the tank needs to be replaced.