AlarmLock PDL3000: Difference between revisions

From Pumping Station One
m Robot: Cosmetic changes
Justin (talk | contribs)
 
(6 intermediate revisions by 3 users not shown)
Line 15: Line 15:


The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf
The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf
* The document may not render the keypad font correctly, making the document useless.
** It fails to render correctly in firefox, and OS X's preview application.
** It renders correctly in [https://get.adobe.com/reader/ Adobe Reader] for OS X.
** It renders correctly in Chrome.


== Sharing the door code ==
== Sharing the door code ==
Line 28: Line 33:


=== Programming the door ===
=== Programming the door ===
To program the door, enter programming mode and enter function codes. All function codes take the form <code>A {function code} (A params) *</code>. While programming mode is enabled, the door will beep every few seconds. You may enter functions until you exit programming mode. To Exit Programming mode, hold down any button for 3 seconds.


<code>{MASTER CODE} A</code>
<code>{MASTER CODE} A</code>
Line 37: Line 45:
<code>A 2 A {User ID} A {CODE} *</code>
<code>A 2 A {User ID} A {CODE} *</code>


==== Deleting =====
==== Deleting ====


<code>A 2 A {USER ID} *</code>
<code>A 2 A {USER ID} *</code>
==== Temporarily Unlocking ====
<code>A 47 A {HOURS} *</code>


== Erasing All Programing ==
== Erasing All Programing ==