{{Template:EquipmentPage|owner=PS:One | {{Template:EquipmentPage|owner=PS:One | ||
|model=Deulux 2 Burner Knife Makers Forge | |model=Deulux 2 Burner Knife Makers Forge | ||
|hostarea=Hot Metals | |||
|serial=N/A | |serial=N/A | ||
|arrived=Yes | |arrived=Yes | ||
|doesitwork= yes | |doesitwork= yes | ||
|contact= | |contact= Ron Olson | ||
|where=Hot Metals Area | |where=Hot Metals Area | ||
|certification=yes | |certification=yes | ||
| Line 36: | Line 37: | ||
#* If the burner still does not light, check the valve on the propane tank is open far enough | #* If the burner still does not light, check the valve on the propane tank is open far enough | ||
#* If the burner does not light after a second attempt '''DO NOT ATTEMPT TO LIGHT IT AGAIN''' contact the area host for instructions on how to proceed. | #* If the burner does not light after a second attempt '''DO NOT ATTEMPT TO LIGHT IT AGAIN''' contact the area host for instructions on how to proceed. | ||
# Once the burner is lit adjust the valve until there is a constant feathered flame | # Once the burner is lit adjust the valve until there is a constant feathered flame. The burners use the venturi effect for the air/fuel mixture. | ||
#* If you are unable to get a constant flame do not use the forge and contact the area host for further instructions | #* If you are unable to get a constant flame do not use the forge and contact the area host for further instructions | ||
# If you require the second burner open the valve for the rear burner 1/8th of a turn and allow it to light | # If you require the second burner open the valve for the rear burner 1/8th of a turn and allow it to light | ||
| Line 66: | Line 67: | ||
* If the liner of the forge has a crack large enough for gas to enter, stop using the forge let the area host know. | * If the liner of the forge has a crack large enough for gas to enter, stop using the forge let the area host know. | ||
* If you encounter an issue with the forge that requires contacting the area host you must place an out of service sign on the forge including why. | * If you encounter an issue with the forge that requires contacting the area host you must place an out of service sign on the forge including why. | ||
[[Category:Hot Metals]] | |||