AlarmLock PDL3000: Difference between revisions

From Pumping Station One
creating door lock page
 
Justin (talk | contribs)
 
(16 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Template:EquipmentPage
{{Template:EquipmentPage
| Owner = PS:One
|owner = PS:One
| model = PDL3000
|model = PDL3000
| hackable = YES
|hackable = yes
| where = Installed on Front Door
|certification = yes
|where = Installed on Front Door
|value = ~$1000
|doesitwork = yes
}}
}}
== Getting an Access Code ==
In order to get the access code, you should A: be a paying member in good standing with the organization, and B: have your [[Bylaws#Eligibility|id checked]] by 2 board members. The best time to get your ID checked is at a general meeting which occur every Tuesday at 8:00pm.
== Reprogramming the Lock ==
The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf
* The document may not render the keypad font correctly, making the document useless.
** It fails to render correctly in firefox, and OS X's preview application.
** It renders correctly in [https://get.adobe.com/reader/ Adobe Reader] for OS X.
** It renders correctly in Chrome.
== Sharing the door code ==
* Please don't share the door code with non-members
* If you don't have the ability to verify membership status, please don't give out the door code.
== Changing the door code ==
Door code logic: each allowed code is associated with a user id between the numbers 12 and 50, inclusive.
The door codes are documented on a ''User Code Record Sheet'' that is stored in the safe.
=== Programming the door ===
To program the door, enter programming mode and enter function codes. All function codes take the form <code>A {function code} (A params) *</code>. While programming mode is enabled, the door will beep every few seconds. You may enter functions until you exit programming mode. To Exit Programming mode, hold down any button for 3 seconds.
<code>{MASTER CODE} A</code>
You are now in program mode until you hold a button for 3 seconds.
==== Adding ====
<code>A 2 A {User ID} A {CODE} *</code>
==== Deleting ====
<code>A 2 A {USER ID} *</code>
==== Temporarily Unlocking ====
<code>A 47 A {HOURS} *</code>
== Erasing All Programing ==
# Remove battery
# Hold down A for 10 seconds (drain the capaciters)
# Reinstall Battery
# withing 5 seconds of hearing 3 beeps, Hold A until it beeps more
# The lock is now reset, the master programming code is now the default.